Concrete electrics poles

Class E pole in reinforced or prestressed concrete

The effort can be applied in all directions

Technical characteristics
  • Dimensional specifications sheets available on request
  • Standard drilling
  • Traceability of the product
  • 4 dowels at the bottom of the support for the shutter of the pole
  • Gray concrete or stained in the mass
  • Regulatory plate Danger of Death
  • Resistance to corrosion E (XS1 – XD1) and freeze / thaw XF1
  • CE marking (performance statements available upon request)
  • Standards EN 12843 and NF C 67 220
  • ISO 9001: 2015 certification
  • Calculation notes and approved manufacturing centers

Class D poles in reinforced or prestressed concrete

The souls of the poles are smooth to avoid a direct way of ascension, for increased security.<br/> Reservations allow the passage of the strips.

Technical characteristics
  • Dimensional specifications sheets available on request
  • Standard drilling
  • Traceability of the product
  • Gray concrete or stained in the mass
  • Regulatory plate Danger of Death
  • Resistance to corrosion E (XS1 – XD1) and freeze / thaw XF1
  • CE marking (performance statements available upon request)
  • Standards EN 12843 and NF C 67 220
  • ISO 9001: 2015 certification
  • Calculation notes and approved manufacturing centers

Reinforced or prestressed concrete pole for overhead power lines

Whether they walk along our roads, punctuate our countryside or be discreet in our villages, concrete poles for airlines have facilitated the rural electrification of our country and are now part of our collective unconscious.

Since the post-war period, this technical product has evolved, both in its mechanical resistance as in its safety aspect.

  • Cells removal to prevent escalation
  • Strips handling to improve the safety of carriers and installers …
  • Pre-drilling in the class D core for the passage of the strips to prevent any climbing on a cutting strap!
  • New self-leveling usage of concretes to improve the manufacturing conditions
  • Poles up to 18 m in height
  • Efforts from 2.5 kN to 40 kN

By mastering the design and calculation notes, EVERWELL can also design specific columns on request. Thus, the production capacity allows to extend the range.

  • Class D up to heights of 20 m or 20 kN
  • Class E up to heights of 18 m or 50 kN

Monopods antennas supports

Whether for radio networks, private networks or various installations, EVERWELL offers a range of telecommunication supports: monopod pylons, masts and antenna supports, reinforced or prestressed concrete, with adaptable height to the topography of the site, to install your equipment (panel antennas, FH antennas, parabolas, rakes …).

  • Mobile telephony
  • Television
  • Broadcasting
  • Other networks such as radars, weather …

A global solution

  • Advice and assistance
  • design and calculation notes
  • Detailed technical file of the antenna support
  • Pylon construction
  • Delivery and lifting on the job

Good beam stability

  • Minimal staking of the barrel
  • even under large antennal loads

A long-term investment

  • Durability of the reinforced or prestressed concrete pylon
  • Intrinsic resistance of the material
  • No specific maintenance of the mast
  • Good weather resistance

Optimal visual integration

  • Low footprint
  • Non-reflective concrete texture
  • Finesse of the monotube silhouette
  • No guying

Accessories line

  • Antenna fixing systems
  • Bearings and platforms
  • Access security
  • Passage and fixing for cables
  • Grounding
  • Lightning equipment …

 63 – 90 – 225 and 400 kV Firewalls for substations
Electrical transformation of specific products

With an in-house design office, the EVERWELL Post Business Unit can make plans, adaptations of its standard products or tailor-made products from your own plans.
A logistics dedicated to the Post activity is adapted to your business management, for a proximity and a better reactivity.

What is a Transformation Station?

  • Voltage transformation (successive lowering to the utilization voltage of the distribution network),
  • Ectricity distribution  to different lines (according to the needs of users)
  • Network protection (eg rapid isolation of a line in circuit breaker from the rest of the healthy network)

Transformation stations are evolving or being created to allow the integration of renewable energies, reception of off-shore wind power, securing of the power supply or its reinforcement or simply to adapt to the evolution of the consumption of an agglomeration.

K2F Facets support (prestressed concrete)

We manufacture concrete supports for 63-90 kV power lines for the creation, security or renovation of overhead lines.

EVERWELL supports specialized electrical engineering companies by developing and adapting its supports to regulatory requirements. Approved supplier, our range of monopod pylons meets several mechanical dimensions to guarantee a resistance to the stresses and the efforts and thus to preserve the safety of the line in service.

  • K2F support
  • KB support
  • KE Support

Calculation notes are carried out by our internal research department and validated by tests also ensures the logistics of support in exceptional convoy and jointly delivers the weapons.