Control cables without screen
Standards:
- Internationals:IEC 60092-350; IEC 60092-360; IEC 60092-376; IEC 60228; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Description / Usage
The color of the product is done accortding to customer order’s. It is used ships for fixed installations, without mechanical risk, in accordance with IEC 60092-352. All materials used to make this cable are halogen free. This design ensures that non-corrosive and low-toxicity gases are emitted in the event of a fire. Therefore, this type of cable is specifically designed for installations on passenger ships, as on other commercial vessels.
Characteristics :
- Nature of the core: Naked Class 2 Naked Copper
- Insulation: XLPE
- Rated operating voltage Uo / U (Um): 0.6 / 1 kV
- Halogen free: IEC 60754-1
- Non- fire propagating: IEC 60332-3-22.
- Non flame retardant: IEC 60332-1
- Maximum temperature on the core: 90 ° C
Control cables with screen
Standards:
- Internationals: IEC 60092-350; IEC 60092-360; IEC 60092-376; IEC 60228; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Description / Usage
The color of the product is given according to the customer’s order.The good shielding qualities of the braid also reduce radio interference and electrical influences to the electronic installation.It is used in ships for fixed installations
Charcateristics:
- Halogen free: IEC 60754-1
- Nature of the core: Naked Class 2 Naked Copper
- Interior lining (Filler, if necessary): Rodé
- Armor: Bare copper braid
- Insulation: XLPE
- Rated operating voltage Uo / U (Um): 0 150/250 (300) V
- Non- fire propagating: IEC 60332-3-22
- Low smoke generation: IEC 61034
Autres câbles de contrôle
Standards:
- Internationals: EN 50618
- Nationals
Description / Usage
They can be of Red or Blue. Other colors are made upon request.
EVERWELL CAMEROON CABLES AND ENGINEERING SA cables are intended for indoor and outdoor photovoltaic applications for flexible or fixed installations
Characteristics:
- Nature of core Tin Coated Copper Class 5 acc. To EN 60228
- Isolation: Halogen-free polyolefin
- Flexibility of the core: Flexible class 5
- Colour central element 1 element = ecru
- Rated operating voltage Uo / U (Um): 1.0 / 1.0 (1.2) kV AC – 1.5 / 1.5 (1.8) kV DC
- Operating ambient temperature, range: -40 … 90 ° C
- Non- fire propagating: C1, NF C 32-070
- Non flame retardant: IEC 60332-1
- Maximum temperature on the core: 120 ° C
Description / Usage
- Cables for reels
- Cables for light garlands
- Crane cables
Description / Usage
- Communication Cables
- HV roof cables & accessories
Which are non-welded, flat-wired power and control cables in PVC or halogen-free versions, supplied in easy-to-install kits, much appreciated by OEMs and repairers.